kVA vs kW: why we ask for both

One number describes the machine. The other describes your load. They are close enough to look interchangeable and different enough to cause expensive mistakes, which is why we ask for both in every requirement.

Two numbers, two different questions

kVA is the capacity of the machine. It is the ceiling on what the alternator can deliver as a whole - the size of the machine, in the units the industry uses for alternator ratings. When a catalogue lists a machine as 100 kVA, that is a statement about the machine and nothing else.

kW is the demand of your load. It is the real power your equipment consumes, and it is the number that has to be covered continuously if you do not want the machine to trip or run overloaded.

They are related through power factor - the ratio between real power and apparent power - and they are related through temperature and altitude, which reduce what a machine can deliver in a given environment. But one is a property of the machine and the other is a property of your site, so they cannot be derived from each other without more information.

Why the industry quotes in kVA

An alternator is limited by how much current it can carry and by how much heat it can move, not by how many kilowatts it can push. Two loads of the same kW but different power factor draw different currents, and the current is what sizes the winding. So the machine is rated in kVA because that is the number that describes its physical capability.

This is also why a genset rating in kVA and an engine output in kW are not the same figure, even on the same set. The engine's output and the alternator's rating are two separate constraints, and the usable machine is the lower of them.

What goes wrong in practice

The load is written as the rating

A requirement that says 100 kVA, 100 kW has quietly assumed a power factor of one. Real loads - motors, drives, lighting, IT - rarely sit there. The result is a machine that is correct on paper and short of current on site.

The rating is copied from a data sheet

A number lifted from a previous order or a catalogue line is not a requirement. It does not say what the load is, what the frequency is, or what the site conditions are, and it cannot be checked against anything.

One number is used for both

If a single figure has to serve as both the rating and the load, the machine is being selected by rounding rather than by engineering. It is the most common single cause of a return visit to the drawing board.

How we handle it

Our inquiry form has a separate field for load in kW and a separate field for machine rating in kVA, and we confirm both in the quotation. We never convert one into the other, because doing so would hide exactly the information you need us to have.

When you send a requirement, the useful content is: the machine rating in kVA, the running load in kW, the duty, the frequency, and the site conditions. Everything else we will ask you for as well - mounting, voltage arrangement, quantity - but those five are what let us start.

A short version

  • kVA is the size of the machine. It comes from the manufacturer, and it is what you are ordering.
  • kW is what your load consumes. It comes from your side, and it is what the machine has to cover.
  • Never convert one into the other without the power factor, the duty and the site conditions.