Excitation is how the alternator creates the magnetic field its winding needs. How that field is supplied decides what the machine can do in a fault, whether it can be run in parallel with another set, and how it behaves when the load is mostly electronic. It is one of the two decisions that change the price most, so it belongs in the requirement rather than in a later conversation.

Why it is a decision and not a detail

Three arrangements cover almost every machine we supply, and the difference between them shows up in three places: what happens when something goes wrong on the board, whether the set can work alongside another one, and how the machine behaves when the load it is feeding is mostly electronics. None of that is visible from the outside of the machine, which is why it has to be written down.

The three are described below in the order most buyers meet them. Where you are still deciding, the checklist page sets out the questions that narrow it down.

Alternator terminal box on a workshop bench
Alternator terminal box
Placeholder - to be replaced with our own photography

The three arrangements

Read the trade-off, not just the name. The arrangement that is right for a single set on its own board is not the one you want on a board where the protection has to discriminate.

self excited

Self-excited

The current in the rotor winding comes from the stator itself. The machine carries its own excitation supply, and nothing external is needed to make the field.

This is the arrangement most sets run with, and it is the right choice when one machine stands alone. It is simple, it needs nothing extra in the control system, and it is the arrangement we assume unless you tell us otherwise.

The limitation is in the fault behaviour. A self-excited machine feeds the fault from its own rotor circuit, which collapses quickly as the voltage falls. That is enough for a fault to be cleared, and not enough for the downstream breaker to discriminate between the fault and a healthy section of the board. On a board with selective coordination, or with several sets running together, that matters.

What you get

  • The simplest arrangement, with no additional control equipment to specify.
  • Adequate fault clearing for a single machine on a board that does not need selective coordination.
  • The lowest cost of the three, which is why it is the default in a quotation.

What you give up

  • Sustained fault current, and with it the ability for the board to coordinate protection selectively.
  • Running two sets in parallel, or working with a significant share of electronic load.

Confirm before quoting

  • Whether more than one set runs on the same board.
  • Whether the protection scheme has to discriminate between outgoing circuits.
  • How much of the load is electronic rather than conventional motor load.
permanent magnet

Permanent magnet

The field comes from a permanent magnet on the rotor rather than from a winding that has to be fed. The machine makes its own field, and the control system does not have to build one.

Because the field does not depend on a supply that collapses under fault conditions, a permanent magnet machine keeps feeding the fault instead of letting go. That is what allows the protection on the board to discriminate properly, and it is why this arrangement is the usual choice for parallel operation and for boards where selective coordination is specified.

The second effect is on the load. A machine with a permanent magnet holds voltage better while the load steps, which is why data centre, telecom and other electronic load applications tend to ask for it by name.

What you get

  • Sustained fault current, so the protection on the board can discriminate between circuits.
  • The arrangement to specify when sets run in parallel.
  • Better voltage holding while an electronic load steps.

What you give up

  • The lowest cost of the three. The magnet and the arrangement around it cost more than the simpler options, and that difference shows up in the quotation.

Confirm before quoting

  • Whether the sets run in parallel.
  • Whether the board protection has to coordinate selectively.
  • How much of the load is electronic.
  • Whether the machine has to work as a single phase unit.
auxiliary winding

Auxiliary winding

A second winding on the rotor carries the field current from an external source, which gives a middle ground between the two arrangements above.

The field is built by a dedicated supply rather than by the machine feeding itself, so the behaviour under fault sits between the two: more capable than a plain self-excited machine, without the cost of the permanent magnet arrangement.

The third thing it does is single phase operation. Machines in this family can be rewired or ordered as a single phase unit, which is what the smaller sets for lighting, site power and small buildings are built on.

What you get

  • A field supply that does not depend on the machine feeding itself.
  • The option to run single phase, by rewiring or by ordering a single phase winding.
  • A middle ground on cost when a full permanent magnet machine is more than the application needs.

What you give up

  • The sustained fault current of the permanent magnet arrangement, if the board protection depends on it.

Confirm before quoting

  • Whether the set runs single phase or three phase.
  • Whether the machine is being rewired, which changes what has to be confirmed before it is ordered.
  • Whether the field supply is available on site or has to come with the machine.

Price

What affects your quote

The quotation is built from the six conditions below. We do not publish a price, because a published number would be wrong for most enquiries.

  1. Power and frequencyMachine rating in kVA and load in kW confirmed separately, at 50 Hz or 60 Hz.
  2. Voltage and winding optionStandard winding or a special voltage, and how many different voltages the set has to carry.
  3. Mounting and mechanical interfaceSingle-bearing SAE or double-bearing, and how it mates to your engine and its housing.
  4. Excitation and short-circuit supportWhether your application needs stronger short-circuit support than the standard arrangement.
  5. Quantity and delivery batchUnits per order, and how many batches you want us to schedule.
  6. Delivery point and trade termsDestination port, and how shipping, insurance and clearance are split between us. EXW, FOB, CIF and DDP can all be quoted.

Send your requirements - a written reply within 24 hours, a selection scheme within 48.

Typical lead time and indicative budget will be confirmed in the formal quotation.

Chat on WhatsApp Business

Ask us

Answers come from published selection notes, not from a catalogue.

Request a quotation

We reply to every enquiry within 24 hours, and a selection scheme follows within 48.