Synchronous AC alternators 250 - 500 kVA
Industrial and project machines, where heat, altitude and the hours of running decide the rating.
250 - 500 kVA · 50 Hz / 60 Hz · 4 pole · Shunt/PMG
Single-bearing on an SAE flange, or double-bearing on a coupling. The two mounting arrangements
What this band covers

| Indicator | Parameter |
|---|---|
| Power range | 250 - 500 kVA |
| Frequency | 50 Hz / 60 Hz |
| Rated voltage | 50 Hz: 400/230 V, 415/240 V, 380/220 V, 220/115 V, 230 V, 115 V 60 Hz: 480/277 V, 440 V/254 V, 240 V/139 V, 208/120 V, 690/400 V, 240 V, 120 V |
| Pole count | 4 pole |
| Excitation system | Shunt/PMG |
| AVR | Shunt standard: AS540, SX440 and similar; PMG standard: MX341*, MX341B*; optional: digital AVR |
| Phases | Three phase |
| Connection | Star (Y) or Delta (D) |
| Insulation class | Class H |
| Protection rating | IP23 standard, IP44 or IP54 optional |
Who buys, and what to confirm before you order
Who buys
Industrial power equipment builders, EPC contractors, and integrators putting standby machines into plants and facilities.
What the machines are used for
Plant standby, industrial sites, continuous duty gensets, and the machines that sit next to a process that cannot stop.
What you need to confirm before you order
- The rated output in kVA and the running load in kW, confirmed separately, including the starting demand of the largest load on the set.
- Whether the machine is prime, standby or emergency duty. A machine that runs all day and one that starts on a grid failure are not the same machine.
- The ambient temperature and the altitude, which set the rating and therefore the size you can install.
- Whether more than one machine works on the same board, and how the protection has to coordinate.
- The mounting style, and whether the engine carries the machine or it runs on its own bearings.
Where the configuration differs
Winding and voltage
At this size a package often carries more than one voltage, and sometimes more than one frequency. Every combination goes into the requirement, because each one changes the winding and the price.
Thermal and insulation
Continuous duty and standby duty are different machines. The rating basis, the insulation margin and the temperature the winding is designed around are all decided here.
Excitation and protection
Where machines run in parallel, or the board has to discriminate between circuits, the excitation arrangement and the fault behaviour have to be specified together.
What affects your quote
- Power and frequencyMachine rating in kVA and load in kW confirmed separately, at 50 Hz or 60 Hz.
- Voltage and winding optionStandard winding or a special voltage, and how many different voltages the set has to carry.
- Mounting and mechanical interfaceSingle-bearing SAE or double-bearing, and how it mates to your engine and its housing.
- Excitation and short-circuit supportWhether your application needs stronger short-circuit support than the standard arrangement.
- Quantity and delivery batchUnits per order, and how many batches you want us to schedule.
- Delivery point and trade termsDestination port, and how shipping, insurance and clearance are split between us. EXW, FOB, CIF and DDP can all be quoted.
Request technical documentation
Send your requirements - a written reply within 24 hours, a selection scheme within 48.
Typical lead time and indicative budget will be confirmed in the formal quotation.
Where to go next
Mounting: single-bearing or double-bearing
The arrangement decides the flange, the bearings and the alignment. It is the one decision that cannot be changed later.
Eight application scenarios
From data centres to marine sets: the load and the conditions that decide the build in each of them.
kVA vs kW: why we ask for both
The two numbers look interchangeable and are not. The difference is what a quotation is built on.
How we inspect and ship
What is checked before the machine leaves, which documents travel with it and how the loading is planned.