Synchronous AC alternators 30 - 100 kVA
Compact sets that still carry a real load, where the starting current and the phase arrangement start to matter.
30 - 100 kVA · 50 Hz / 60 Hz · 4 pole · Shunt/PMG
Single-bearing on an SAE flange, or double-bearing on a coupling. The two mounting arrangements
What this band covers

| Indicator | Parameter |
|---|---|
| Power range | 30 - 100 kVA |
| Frequency | 50 Hz / 60 Hz |
| Rated voltage | 50 Hz: 400/230 V, 415/240 V, 380/220 V, 220/115 V, 230 V, 115 V 60 Hz: 480/277 V, 440 V/254 V, 240 V/139 V, 208/120 V, 240 V, 120 V |
| Pole count | 4 pole |
| Excitation system | Shunt/PMG |
| AVR | Shunt standard: AS540, SX460* and similar; PMG standard: MX341*, MX341B*; optional: digital AVR |
| Phases | Three phase |
| Connection | Star (Y) or Delta (D) |
| Insulation class | Class H |
| Protection rating | IP23 standard, IP44 or IP54 optional |
Who buys, and what to confirm before you order
Who buys
Small genset manufacturers, mobile and towable set builders, light commercial standby integrators, and rental fleet operators.
What the machines are used for
Mobile site power, small shops and clinics on standby, small construction sites, and light tower sets where the machine runs for hours at a stretch.
What you need to confirm before you order
- Single phase or three phase, and whether the single phase output comes from a reconnected winding or a dedicated one.
- The engine speed the alternator must run at, and the frequency it has to hold (50 Hz or 60 Hz).
- The mounting style, and the shaft and housing dimensions your engine uses.
- How long the set runs per day, because that changes the rating basis and the insulation margin.
- The ambient temperature, and whether the set runs in an open frame or under a canopy.
Where the configuration differs
Winding and voltage
Both single phase and three phase arrangements are available at this size, and a reconnected winding and a dedicated one do not behave the same way on site. We confirm which your electrical drawing expects.
Excitation
Shunt excitation is the usual arrangement here. Where several machines share a board, or the protection has to discriminate between circuits, the excitation arrangement stops being a default.
Enclosure
Open frame, canopy and container each move the air differently. A set that runs for hours in dust needs its cooling path and its filters planned at the same time.
What affects your quote
- Power and frequencyMachine rating in kVA and load in kW confirmed separately, at 50 Hz or 60 Hz.
- Voltage and winding optionStandard winding or a special voltage, and how many different voltages the set has to carry.
- Mounting and mechanical interfaceSingle-bearing SAE or double-bearing, and how it mates to your engine and its housing.
- Excitation and short-circuit supportWhether your application needs stronger short-circuit support than the standard arrangement.
- Quantity and delivery batchUnits per order, and how many batches you want us to schedule.
- Delivery point and trade termsDestination port, and how shipping, insurance and clearance are split between us. EXW, FOB, CIF and DDP can all be quoted.
Request technical documentation
Send your requirements - a written reply within 24 hours, a selection scheme within 48.
Typical lead time and indicative budget will be confirmed in the formal quotation.
Where to go next
Mounting: single-bearing or double-bearing
The arrangement decides the flange, the bearings and the alignment. It is the one decision that cannot be changed later.
Eight application scenarios
From data centres to marine sets: the load and the conditions that decide the build in each of them.
kVA vs kW: why we ask for both
The two numbers look interchangeable and are not. The difference is what a quotation is built on.
How we inspect and ship
What is checked before the machine leaves, which documents travel with it and how the loading is planned.